86

Chan Off

Indicates the source channel is not
activated.

Note

Before using this command, select the
measurement channel. See the example below.

Example

:MEASure:SOURce1 CH1
:MEASure:PERiod?
1.0E-3
Selects Channel 1, and then measures the period.

:MEASure:PWIDth

Description

Returns the first positive pulse width.

Syntax

:MEASure:PWIDth{?}

Related
Commands

:MEASure:SOURce

Return parameter

Returns the positive pulse width.

Chan Off

Indicates the source channel is not
activated.

Note

Before using this command, select the
measurement channel. See the example below.

Example

:MEASure:SOURce1 CH1
:MEASure:PWIDth?
5.0E-6
Selects Channel 1, and then measures the positive
pulse width.

:MEASure:RISe

Description

Returns the first pulse rise time.

Syntax

:MEASure:RISe{?}

Related
Commands

:MEASure:SOURce

Query

Query