COMMAND DETAILS

83

:MEASure:FOVShoot

Description

Returns the fall overshoot amplitude.

Syntax

:MEASure:FOVShoot{?}

Related
Commands

:MEASure:SOURce

Return parameter

Returns the fall overshoot as a
percentage

Chan Off

Indicates the source channel is not
activated.

Note

Before using this command, select the
measurement channel. See the example below.

Example

:MEASure:SOURce1 CH1
:MEASure:FOVShoot?
1.27E+0
Selects Channel 1, and then measures the fall
overshoot.

:MEASure:FPReshoot

Description

Returns fall preshoot amplitude.

Syntax

:MEASure:FPReshoot{?}

Related
Commands

:MEASure:SOURce

Returns

Returns the fall preshoot as .

Return parameter

Returns the fall preshoot as a percentage.

Chan Off

Indicates the source channel is not
activated.

Note

Before using this command, select the
measurement channel. See the example below.

Query

Query