:TRIGger:EXTERnal:PROBe:TYPe

Description

Sets or queries the external probe type.

Syntax

:TRIGger:EXTERnal:PROBe:TYPe { VOLTage | CURRent
| ? }

Related
commands

:TRIGger:EXTERnal:PROBe:RATio

Parameter

VOLTage

Voltage

CURRent

Current

Return parameter

Returns the probe type.

Example

:TRIGger:EXTERnal:PROBe:TYPe?
CURRENT

:TRIGger:EXTERnal:PROBe:RATio

Description

Sets or queries the external probe ratio
(attenuation).

Syntax

:TRIGger:EXTERnal:PROBe:RATio { | ?}

Related
commands

:TRIGger:EXTERnal:PROBe:TYPe

Parameter

External probe attenuation factor.

Return parameter

Returns the probe attenuation factor.

Example

:TRIGger:EXTERnal:PROBe:RATio?
5.000000e+01

:TRIGger:BUS:TYPe

Description

Returns the current bus type.

Syntax

:TRIGger:BUS:TYPe?

Return parameter 12C

I2C mode