beautypg.com

Measure:method, Measure:fall – GW Instek GDS-2000A series Programming Manual User Manual

Page 82

background image

GDS-2000A Programming Manual

82

:MEASure:METHod

Description

Sets or queries the method used to determine the
High-Low measurement values.

Syntax

:MEASure:METHod { AUTo | HIStogram | MINMax
| ? }

Parameter

AUTo

Set to auto.

HIStogram Set to the Histogram method.

MINMax

Set to the Min-Max method.

Return parameter

Returns the measurement method (AUTO,
HISTOGRAM, MINMAX)

Example

:MEASure:METHod: AUTo

Set the measurement method to auto.

:MEASure:FALL

Description

Returns the fall time measurement result.

Syntax

:MEASure:FALL{?}

Related
Commands

:MEASure:SOURce

Return parameter

Chan Off

Indicates the source channel is not
activated.

Note

Before using this command, select the
measurement channel. See the example below.

Example

:MEASure:SOURce1 CH1
:MEASure:FALL?
Selects Channel 1 as the source, and then measures
the fall time.

Set

Query

Query