beautypg.com

Trigger:bus:b1:lin:data:qualifier – GW Instek GDS-2000A series Programming Manual User Manual

Page 156

background image

GDS-2000A Programming Manual

156

Example

:TRIGger:BUS:B1:LIN:CONDition?
>IDANDDATA
:TRIGger:BUS:B1:LIN:CONDition DATA
:TRIGger:BUS:B1:LIN:CONDition?
>DATA

:TRIGger:BUS:B1:LIN:DATa:QUALifier

Description

Sets or returns the LIN data qualifier.
Note: Only applicable when the trigger condition
is set to DATA or IDANDDATA.
Requirements: Firmware version V1.19 or later with
DS2-LA8 (or DS2-LA16).

Syntax

:TRIGger:BUS:B1:LIN:DATa:QUALifier
{LESSthan|THAN|EQual|UNEQual|LESSEQual|MORE
EQual|?}

Parameter/
Return parameter

LESSthan

Triggers when the data is less than
the qualifier value.

THAN

Triggers when the data is greater than
the qualifier value.

EQual

Triggers when the data is equal to the
qualifier value.

UNEQual

Triggers when the data is not equal to
the qualifier value.

LESSEQual

Triggers when the data is less than or
equal to the qualifier value.

MOREEQual

Triggers when the data is more than
or equal to the qualifier value.

LESSthan

Triggers when the data is less than
the qualifier value.

Set

Query