378
Multi-Service IronWare Administration Guide
53-1003028-02
Syslog messages
A
Notification
Session DOWN for RSVP session session-id
Reason Administratively Down
The BFD session for the RSVP session
specified by the session-id is Down for
Administrative reasons.
The form of the session-id displayed is
IPv4 tunnel endpoint or tunnel ID or
extended tunnel ID.
For example 10.22.22.2/3/11/11/11/1
Notification
Session UP for RSVP session session-id
The BFD session for the RSVP session
specified by the session-id is Up.
The form of the session-id displayed is
IPv4 tunnel endpoint or tunnel ID or
extended tunnel ID.
For example 10.22.22.2/3/11/11/11/1
Notification
Transceiver type checking has been
enabled!
The transceiver type checking feature has
been re-enabled. The feature is enabled by
default and does not send the message
under normal circumstances. However, if it
is disabled and then re-enabled the device
will send this message.
Warning
Optic is not Brocade qualified (port) Type
type-description
Vendor vendor-name, Version version-num
Part# part-no,
Serial# serial-no
The optic module installed in the Interface
module at the port specified by the port
variable is not Brocade qualified although
the port is still operational. The Type,
Vendor, Version, Part#, and Serial # of the
optic module is provided.
Alert
Optic is not Brocade qualified, optical
monitoring is not supported (port)
Type type-description
Vendor vendor-name, Version version-num
Part# part-no,
Serial#serial-no
The optic module installed in the Interface
module at the port specified by the port
variable is not Brocade qualified and will
not be able to be monitored using the
Optical Monitoring function. The Type,
Vendor, Version, Part#, and Serial # of the
optic module is provided.
Alert
Optic is not capable of optical monitoring
(port)
Type type-description
Vendor vendor-name, Version version-num
Part# part-no,
Serial# serial-no
The optic module installed in the Interface
module at the port specified by the port
variable is not able to be monitored using
the Optical Monitoring function. The Type,
Vendor, Version, Part#, and Serial # of the
optic module is provided.
Alert
Incompatible optical trans-receiver
detected on port n
Indicates that in incompatible XFP or SFP
has been installed in the port specified. A
port with an incompatible optical module
installed are shut down.
TABLE 85
Syslog messages Optics (Continued)
Message level
Message
Explanation