Synthetic loss measurement

6

Syntax: Show cfm loss-measurement slm statistics session index

DUT1# show cfm loss-measurement slm statistics 1

HISTORY TABLE :

Flag - S:Suspect

-----------------------------------------------------------------------------------------------

Index Flag Start Elapsed TxFwd RxFwd TxBck RxBck FLR(ratio) BLR(ratio)

-----------------------------------------------------------------------------------------------

5 - 16:29:56 00:00:05 5 5 5 5 0.00000 0.00000

4 - 16:29:39 00:00:14 14 4 4 4 0.71428 0.00000

3 - 16:29:25 00:00:04 4 0 0 0 1.00000 0.00000

2 - 16:29:17 00:00:03 3 0 0 0 1.00000 0.00000

1 - 16:27:14 00:00:03 3 0 0 0 1.00000 0.00000

==============================================================================================

Syntax: show cfm loss-measurement slm statistics detailed session_index row index

DUT1# show cfm loss-measurement slm statistics detailed 1 2

HISTORY TABLE :

Flag - S:Suspect

------------------------------------------------

Index : 2

Flag : -

Start : 16:29:56

Elapsed : 00:00:05

TxFwd : 5

RxFwd : 5

TxBck : 5

RxBck : 5

FLR(ratio) Max : 0.00000

Session Type

initiator or responder

Domain

domain name

MA

ma name

Source MEP

source mep id

Target MEP

target mep id or RMEP

COS

data priority loss in which needs to be monitored

Start time

Configured start time

Start time type

Immediate, relative, fixed, periodic

Stop time

configured stop time

Stop time type

Immediate, relative, fixed, periodic

Tx interval (sec)

transmission interval in sec, only for initiator

Measurement interval

measurement-interval in minutes, only for initiator

Forward Average

configured forward average threshold, for initiator

Forward Max

configured forward maximum threshold, for initiator

Backward Average

configured backward average threshold, for initiator

Backward Max

configured backward maximum threshold, for initiator

TABLE 35

show cfm loss-measurement slm output

Row

Definition