Brocade Multi-Service IronWare Administration Guide (Supporting R05.6.00) User Manual
Page 272

254
Multi-Service IronWare Administration Guide
53-1003028-02
Synthetic loss measurement
6
DUT2 Configuration
DUT2(config)# cfm
DUT2(config-cfm)# loss-measurement slm responder 1
DUT2(config-cfm-loss-measurement-slm-responder-1)#domain md1 ma ma1 src-mep 4
target-mep 3
DUT2(config-cfm-loss-measurement-slm-responder-1)#cos 2
Starting synthetic loss measurement sessions:
NOTE
Start the synthetic loss measurement (SLM) session on the responder side before the initiator.
DUT2 Configuration (Responder)
DUT2(config)# cfm
DUT2(config-cfm)# cfm loss-measurement slm responder 1
DUT2(config-cfm-loss-measurement-slm-responder-1)#start now
DUT1 Configuration (Initiator)
DUT1(config)# cfm
DUT1(config-cfm)# cfm loss-measurement slm initiator 1
DUT1(config-cfm-loss-measurement-slm-initiator-1)#start now
Stopping synthetic loss measurement sessions:
NOTE
Stop the initiator before stopping the responder.
DUT1 Configuration
DUT1(config)# cfm
DUT1(config-cfm)# cfm loss-measurement slm initiator 1
DUT1(config-cfm-loss-measurement-slm-initiator-1)#stop now
DUT2 Configuration
DUT2(config)# cfm
DUT2(config-cfm)# cfm loss-measurement slm responder 1
DUT2(config-cfm-loss-measurement-slm-responder-1)#stop now
Clearing loss statistics:
You can clear history statistics on the initiator side at any point of time using the following
command.
DUT1(config)# cfm
DUT1(config-cfm)# cfm loss-measurement slm initiator 1
DUT1(config-cfm-loss-measurement-slm-initiator-1)#clear-stat
You can clear the history statistics globally using the following command.
NOTE
When this command is executed, history logs will be cleared for all sessions in the system.
DUT1(config)# cfm
DUT1(config-cfm)# cfm loss-measurement slm clear-stat