beautypg.com

Brocade Multi-Service IronWare Administration Guide (Supporting R05.6.00) User Manual

Page 272

background image

254

Multi-Service IronWare Administration Guide

53-1003028-02

Synthetic loss measurement

6

DUT2 Configuration

DUT2(config)# cfm

DUT2(config-cfm)# loss-measurement slm responder 1

DUT2(config-cfm-loss-measurement-slm-responder-1)#domain md1 ma ma1 src-mep 4

target-mep 3

DUT2(config-cfm-loss-measurement-slm-responder-1)#cos 2

Starting synthetic loss measurement sessions:

NOTE

Start the synthetic loss measurement (SLM) session on the responder side before the initiator.

DUT2 Configuration (Responder)

DUT2(config)# cfm

DUT2(config-cfm)# cfm loss-measurement slm responder 1

DUT2(config-cfm-loss-measurement-slm-responder-1)#start now

DUT1 Configuration (Initiator)

DUT1(config)# cfm

DUT1(config-cfm)# cfm loss-measurement slm initiator 1

DUT1(config-cfm-loss-measurement-slm-initiator-1)#start now

Stopping synthetic loss measurement sessions:

NOTE

Stop the initiator before stopping the responder.

DUT1 Configuration

DUT1(config)# cfm

DUT1(config-cfm)# cfm loss-measurement slm initiator 1

DUT1(config-cfm-loss-measurement-slm-initiator-1)#stop now

DUT2 Configuration

DUT2(config)# cfm

DUT2(config-cfm)# cfm loss-measurement slm responder 1

DUT2(config-cfm-loss-measurement-slm-responder-1)#stop now

Clearing loss statistics:
You can clear history statistics on the initiator side at any point of time using the following
command.

DUT1(config)# cfm

DUT1(config-cfm)# cfm loss-measurement slm initiator 1

DUT1(config-cfm-loss-measurement-slm-initiator-1)#clear-stat

You can clear the history statistics globally using the following command.

NOTE

When this command is executed, history logs will be cleared for all sessions in the system.

DUT1(config)# cfm

DUT1(config-cfm)# cfm loss-measurement slm clear-stat