Synthetic loss measurement
6
Starting synthetic loss measurement sessions:
LER2 Configuration (Responder)
LER2(config)# cfm
LER2(config-cfm)# cfm loss-measurement slm responder 1
LER2(config-cfm-loss-measurement-slm-responder-1)#start now
LER1 Configuration (Initiator)
LER1(config)# cfm
LER1(config-cfm)# cfm loss-measurement slm initiator 1
LER1(config-cfm-loss-measurement-slm-initiator-1)#start now
Stopping synthetic loss measurement sessions:
NOTE
Stop the initiator before stopping the responder.
LER1 Configuration
LER1(config)# cfm
LER1(config-cfm)# cfm loss-measurement slm initiator 1
LER1(config-cfm-loss-measurement-slm-initiator-1)#stop now
LER2 Configuration
LER2(config)# cfm
LER2(config-cfm)# cfm loss-measurement slm responder 1
LER2(config-cfm-loss-measurement-slm-responder-1)#stop now
Clearing loss statistics:
You can clear history statistics on the initiator side at any time using the following command.
LER1(config)# cfm
LER1(config-cfm)# cfm loss-measurement slm initiator 1
LER1(config-cfm-loss-measurement-slm-initiator-1)#clear-stat
You can clear the history statistics globally using the following command.
NOTE
When this command is executed, history logs will be cleared for all sessions in the system.
LER1(config)# cfm
LER1(config-cfm)# cfm loss-measurement slm clear-stat
Sample configuration - Synthetic loss measurement over VLL
Starting synthetic loss measurement sessions:
NOTE
Start the synthetic loss measurement (SLM) session on the responder side before the initiator.
LER2 Configuration (Responder)
LER2(config)# cfm
LER2(config-cfm)# cfm loss-measurement slm responder 1
LER2(config-cfm-loss-measurement-slm-responder-1)#start now