Synthetic loss measurement

6

Starting synthetic loss measurement sessions:
LER2 Configuration (Responder)

LER2(config)# cfm

LER2(config-cfm)# cfm loss-measurement slm responder 1

LER2(config-cfm-loss-measurement-slm-responder-1)#start now

LER1 Configuration (Initiator)

LER1(config)# cfm

LER1(config-cfm)# cfm loss-measurement slm initiator 1

LER1(config-cfm-loss-measurement-slm-initiator-1)#start now

Stopping synthetic loss measurement sessions:

NOTE

Stop the initiator before stopping the responder.

LER1 Configuration

LER1(config)# cfm

LER1(config-cfm)# cfm loss-measurement slm initiator 1

LER1(config-cfm-loss-measurement-slm-initiator-1)#stop now

LER2 Configuration

LER2(config)# cfm

LER2(config-cfm)# cfm loss-measurement slm responder 1

LER2(config-cfm-loss-measurement-slm-responder-1)#stop now

Clearing loss statistics:
You can clear history statistics on the initiator side at any time using the following command.

LER1(config)# cfm

LER1(config-cfm)# cfm loss-measurement slm initiator 1

LER1(config-cfm-loss-measurement-slm-initiator-1)#clear-stat

You can clear the history statistics globally using the following command.

NOTE

When this command is executed, history logs will be cleared for all sessions in the system.

LER1(config)# cfm

LER1(config-cfm)# cfm loss-measurement slm clear-stat

Sample configuration - Synthetic loss measurement over VLL

Starting synthetic loss measurement sessions:

NOTE

Start the synthetic loss measurement (SLM) session on the responder side before the initiator.

LER2 Configuration (Responder)

LER2(config)# cfm

LER2(config-cfm)# cfm loss-measurement slm responder 1

LER2(config-cfm-loss-measurement-slm-responder-1)#start now