Brocade Multi-Service IronWare Administration Guide (Supporting R05.6.00) User Manual
Page 361

Multi-Service IronWare Administration Guide
343
53-1003028-02
Syslog messages
A
Error
Error Module down in slot 3, reason
CARD_DOWN_REASON_BOOT_FAILED.Err
or Code (1).
•
The error message displayed on the
Management Module console when the
Interface Module fails to boot up. The
message will display the error code reason.
•
When the Interface Module is in DOWN state,
the error code is included in the dynamic
buffer.
The error code is 0 when there is no error code
reported from the Interface Module.
Warning
CAM partition partition name warning
total total-count, free current free-count,
slot slot-number, ppcr ppcr-id
Indicates that the CAM partition specified by the
partition name has exceeded a threshold
(configurable with a default value of within 5% of
the capacity of the partition) and may soon
overflow the threshold. The free-count specifies
the amount of free space still available in the
partition. The slot-number and ppcr ppcr-id
indicate where the overflow is occurring.
The partition-name includes the sub-partition ID if
applicable.
Warning
System Not enough power to power on
module in slot num
There is not enough power available in the
chassis to power on the module in the specific
slot number.
The slot num refers to the slot number in the
chassis.
Notification
System Module up in slot n
Notification
System Module down in slot n reason
Indicates that the module in the slot specified by
the n variable is down for one of the following
reasons as specified by the reason variable:
•
CARD_DOWN_REASON_NONE
•
CARD_DOWN_REASON_ADMIN_DOWN
•
CARD_DOWN_REASON_CONFIG_MISMATCH
•
CARD_DOWN_REASON_LOSS_HEARTBEAT
•
CARD_DOWN_REASON_BOOT_FAILED
•
CARD_DOWN_REASON_TIMEOUT
•
CARD_DOWN_REASON_STRIPE_SYNC_FAILED
•
CARD_DOWN_REASON_REBOOTED
•
CARD_DOWN_REASON_OVER_HEAT
•
CARD_DOWN_REASON_POWERED_OFF_BY_US
ER
•
CARD_DOWN_REASON_LINK_DOWN
Notification
System Module n powered on
Notification
System Module n powered off
Notification
System Switch fabric n powered on
Notification
System Switch fabric n powered off
Notification
System Enough power available to power
on module in slot num.
There is enough power available in the chassis to
power on the module in the specific slot number.
The slot num refers to the slot number in the
chassis.
TABLE 58
Syslog messages system (Continued)
Message level
Message
Explanation