Syslog messages
A
Error
Error Module down in slot 3, reason 
CARD_DOWN_REASON_BOOT_FAILED.Err
or Code (1).
•
The error message displayed on the 
Management Module console when the 
Interface Module fails to boot up. The 
message will display the error code reason.
•
When the Interface Module is in DOWN state, 
the error code is included in the dynamic 
buffer.
The error code is 0 when there is no error code 
reported from the Interface Module.
Warning
CAM partition partition name warning 
total total-count, free current free-count, 
slot slot-number, ppcr ppcr-id
Indicates that the CAM partition specified by the 
partition name has exceeded a threshold 
(configurable with a default value of within 5% of 
the capacity of the partition) and may soon 
overflow the threshold. The free-count specifies 
the amount of free space still available in the 
partition. The slot-number and ppcr ppcr-id 
indicate where the overflow is occurring.
The partition-name includes the sub-partition ID if 
applicable.
Warning
System Not enough power to power on 
module in slot num
There is not enough power available in the 
chassis to power on the module in the specific 
slot number.
The slot num refers to the slot number in the 
chassis.
Notification
System Module up in slot n
Notification
System Module down in slot n reason
Indicates that the module in the slot specified by 
the n variable is down for one of the following 
reasons as specified by the reason variable:
•
CARD_DOWN_REASON_NONE
•
CARD_DOWN_REASON_ADMIN_DOWN
•
CARD_DOWN_REASON_CONFIG_MISMATCH
•
CARD_DOWN_REASON_LOSS_HEARTBEAT
•
CARD_DOWN_REASON_BOOT_FAILED
•
CARD_DOWN_REASON_TIMEOUT
•
CARD_DOWN_REASON_STRIPE_SYNC_FAILED
•
CARD_DOWN_REASON_REBOOTED
•
CARD_DOWN_REASON_OVER_HEAT
•
CARD_DOWN_REASON_POWERED_OFF_BY_US
ER
•
CARD_DOWN_REASON_LINK_DOWN
Notification
System Module n powered on
Notification
System Module n powered off
Notification
System Switch fabric n powered on
Notification
System Switch fabric n powered off
Notification
System Enough power available to power 
on module in slot num.
There is enough power available in the chassis to 
power on the module in the specific slot number.
The slot num refers to the slot number in the 
chassis.
TABLE 58
Syslog messages system (Continued)
Message level
Message
Explanation