Synthetic loss measurement
6
DUT(config-cfm-loss-measurement-slm-initiator-1)# tx-interval 1
Syntax: measurement-interval interval
Interval - is used to configure SLM Measurement interval (default- 15min).
DUT(config-cfm-loss-measurement-slm-initiator-1)# threshold forward
Syntax: threshold [forward | backward] [average | maximum] value
Default values
Threshold Forward Average 0xFFFFFFFF mili-percent
Threshold Backward Average 0xFFFFFFFF mili-percent
Threshold Forward maximum 0xFFFFFFFF mili-percent
Threshold Backward maximum 0xFFFFFFFF mili-percent
Configuration examples
Sample configuration of synthetic loss measurement over VLAN
VLAN Configurations:
DUT1 Configuration
DUT1(config)# vlan 2
DUT1(config-vlan-2)# tagged ethernet 1/1
DUT2 Configuration
DUT2(config)# vlan 2
DUT2(config-vlan-2)# tagged ethernet 1/1
CFM Configurations:
DUT1 Configuration
DUT1(config)# cfm-enable
DUT1(config-cfm)# domain md1 level 7
DUT1(config-cfm-md-md1)# ma ma1 vlan 10 priority 4
DUT1(config-cfm-md-md1-ma-ma1)# mep 3 down port ethernet 1/1
DUT2 Configuration
DUT2(config)# cfm-enable
DUT2(config-cfm)# domain md1 level 7
DUT2(config-cfm-md-md1)# ma ma1 vlan 2 priority 4
DUT2(config-cfm-md-md1-ma-ma1)# mep 4 down port ethernet 1/1
SLM Configurations:
DUT1 Configuration
DUT1(config)# cfm
DUT1(config-cfm)# loss-measurement slm initiator 1
DUT1(config-cfm-loss-measurement-slm-initiator-1)#domain md1 ma ma1 src-mep 3
target-mep 4
DUT1(config-cfm-loss-measurement-slm-initiator-1)#cos 2
DUT1(config-cfm-loss-measurement-slm-initiator-1)#tx-interval 1
DUT1(config-cfm-loss-measurement-slm-initiator-1)#measurement-interval 1