Frame Loss Measurement

6

BrocadeCE-2(config-cfm-loss-measurement-lmm-responder-1)#domain md1 ma ma1

src-mep 4 target-mep 3

BrocadeCE-2(config-cfm-loss-measurement-lmm-responder-1)#Cos 2

Configuration example for VPLS tagged endpoints

PE-1 Configuration (Initiator)

BrocadePE-1(config-cfm)# loss-measurement lmm initiator 1

BrocadePE-1(config-cfm-loss-measurement-lmm-initiator-1)#domain md1 ma ma1

src-mep 3 target-mep 4

BrocadePE-1(config-cfm-loss-measurement-lmm-initiator-1)#Cos 2

BrocadePE-1(config-cfm-loss-measurement-lmm-initiator-1)#tx-interval 10

BrocadePE-1(config-cfm-loss-measurement-lmm-initiator-1)#measurement-interval 10

PE-2 Configuration (Responder)

BrocadePE-2(config-cfm)# loss-measurement lmm responder 1

BrocadePE-2(config-cfm-loss-measurement-lmm-responder-1)#domain md1 ma ma1

src-mep 4 target-mep 3

BrocadePE-2(config-cfm-loss-measurement-lmm-responder-1)#Cos 2

Configuration example for VPLS untagged endpoints

PE-1 Configuration (Initiator)

BrocadePE-1(config-cfm)# loss-measurement lmm initiator 1

BrocadePE-1(config-cfm-loss-measurement-lmm-initiator-1)#domain md1 ma ma1

src-mep 3 target-mep 4

BrocadePE-1(config-cfm-loss-measurement-lmm-initiator-1)#Cos 8

BrocadePE-1(config-cfm-loss-measurement-lmm-initiator-1)#tx-interval 10

BrocadePE-1(config-cfm-loss-measurement-lmm-initiator-1)#measurement-interval 10

PE-2 Configuration (Responder)

BrocadePE-2(config-cfm)# loss-measurement lmm responder 1

BrocadePE-2(config-cfm-loss-measurement-lmm-responder-1)#domain md1 ma ma1

src-mep 4 target-mep 3

BrocadePE-2(config-cfm-loss-measurement-lmm-responder-1)#Cos 8

Configuration example for VPLS tagged and untagged endpoints

PE-1 Configuration (Initiator)

BrocadePE-1(config-cfm)# loss-measurement lmm initiator 1

BrocadePE-1(config-cfm-loss-measurement-lmm-initiator-1)#domain md1 ma ma1

src-mep 3 target-mep 4

BrocadePE-1(config-cfm-loss-measurement-lmm-initiator-1)#Cos 8

BrocadePE-1(config-cfm-loss-measurement-lmm-initiator-1)#tx-interval 10

BrocadePE-1(config-cfm-loss-measurement-lmm-initiator-1)#measurement-interval 10

PE-2 Configuration (Responder)

BrocadePE-2(config-cfm)# loss-measurement lmm responder 1

BrocadePE-2(config-cfm-loss-measurement-lmm-responder-1)#domain md1 ma ma1

src-mep 4 target-mep 3

BrocadePE-2(config-cfm-loss-measurement-lmm-responder-1)#Cos 8