Brocade Multi-Service IronWare Administration Guide (Supporting R05.6.00) User Manual
Page 360

342
Multi-Service IronWare Administration Guide
53-1003028-02
Syslog messages
A
Alert
System Management module at slot 
slot-num state changed from 
module-state to module-state due to 
reason.
Indicates a state change in a management 
module.
The slot-num indicates the chassis slot containing 
the module.
The module-state can be one of the following:
•
active
•
standby
•
crashed
•
coming-up
•
unknown
A due to clause has been added to this message. 
The reason variable can be either or the following:
•
MP upgrade to ver version number where 
version number is the version number of the 
Multi-Service IronWare software that the 
management module was upgraded to.
•
Active Reboot
Alert
System Temperature degrees C degrees, 
warning level warn-degrees C degrees, 
shutdown level shutdown-degrees C 
degrees
Indicates an overtemperature condition on the 
active module. 
The degrees value indicates the temperature of 
the module.
The warn-degrees value is the warning threshold 
temperature configured for the module.
The shutdown-degrees value is the shutdown 
temperature configured for the module.
Alert
System num-modules modules and 1 
power supply, need more power supply!
Indicates that the chassis needs more power 
supplies to run the modules in the chassis.
The num-modules parameter indicates the 
number of modules in the chassis.
Alert
System: Health Monitoring: FE access 
failure detected on SFM num/FE num
(NetIron XMR and NetIron MLX only)
The management processor is unable to access 
the specified fabric element. This syslog message 
will be generated a maximum of once per ten 
minute period.
The SFM and FE num parameters indicate the 
number of the switch fabric module and fabric 
element that could not be accessed
Alert
System: Health Monitoring: TM Egress 
data errors detected on LP num/TM num
The system has detected egress data errors on 
the specified line processor and traffic manager.
The LP and TM num parameters indicate the 
number of the line processor and traffic manager 
on which the errors were detected.
Error
Error Failed to shutdown Power Supply 
PS-Num. Write Failed (offset 0x2, value 
44, size 2).(Brocade NetIron XMR and 
Brocade MLX only).
A power supply failed to shutdown because of its 
failure to access its registers.
TABLE 58
Syslog messages system (Continued)
Message level
Message
Explanation