342

Multi-Service IronWare Administration Guide

53-1003028-02

Syslog messages

A

Alert

System Management module at slot
slot-num state changed from
module-state to module-state due to
reason.

Indicates a state change in a management
module.
The slot-num indicates the chassis slot containing
the module.
The module-state can be one of the following:

active

standby

crashed

coming-up

unknown

A due to clause has been added to this message.
The reason variable can be either or the following:

MP upgrade to ver version number where
version number is the version number of the
Multi-Service IronWare software that the
management module was upgraded to.

Active Reboot

Alert

System Temperature degrees C degrees,
warning level warn-degrees C degrees,
shutdown level shutdown-degrees C
degrees

Indicates an overtemperature condition on the
active module.
The degrees value indicates the temperature of
the module.
The warn-degrees value is the warning threshold
temperature configured for the module.
The shutdown-degrees value is the shutdown
temperature configured for the module.

Alert

System num-modules modules and 1
power supply, need more power supply!

Indicates that the chassis needs more power
supplies to run the modules in the chassis.
The num-modules parameter indicates the
number of modules in the chassis.

Alert

System: Health Monitoring: FE access
failure detected on SFM num/FE num
(NetIron XMR and NetIron MLX only)

The management processor is unable to access
the specified fabric element. This syslog message
will be generated a maximum of once per ten
minute period.
The SFM and FE num parameters indicate the
number of the switch fabric module and fabric
element that could not be accessed

Alert

System: Health Monitoring: TM Egress
data errors detected on LP num/TM num

The system has detected egress data errors on
the specified line processor and traffic manager.
The LP and TM num parameters indicate the
number of the line processor and traffic manager
on which the errors were detected.

Error

Error Failed to shutdown Power Supply
PS-Num. Write Failed (offset 0x2, value
44, size 2).(Brocade NetIron XMR and
Brocade MLX only).

A power supply failed to shutdown because of its
failure to access its registers.

TABLE 58

Syslog messages system (Continued)

Message level

Message

Explanation