beautypg.com

Provider bridge brocade1 – Brocade Multi-Service IronWare Administration Guide (Supporting R05.6.00) User Manual

Page 184

background image

166

Multi-Service IronWare Administration Guide

53-1003028-02

CFM monitoring and show commands

6

1. Create the port-based VLAN that contains the tagged interface that you want to use by entering

the following commands.

RouterC(config)# vlan30

RouterC(config-vlan-30)# tagged ethe 1/1

2. To enable CFM, enter the following command.

RouterC(config)#cfm-enable

3. Create a maintenance domain with a specified name CUST_1 and level 7.

RouterC(config-cfm)#domain-name CUST_1 level 7

4. Create a maintenance association within a specified ESI Site3vlan30, and a vlan-id 30 with a

priority 3.

RouterC(config-cfm-md-CUST_1)#ma-name ma_5 esi Site3vlan30 vlan-id 30 priority

3

5. Set the time interval between successive Continuity Check Messages to 10-seconds.

RouterC(config-cfm-md-CUST_1-ma-ma_5)#ccm-interval 10-second

6. Configuring a MED for each of the Domain Service Access Points of a service instance creates

a MA to monitor the connectivity. Add ethernet port 1/2 to a specified maintenance
association.

RouterC(config-cfm-md-CUST_1-ma-ma_5)#mep 2 down port ethe 1/2

7. To configure the hostnameas RouterC, enter a command such as the following.

RouterC(config)#hostname RouterC

8. Configure interface ethernet 1/1 as the custome-edge by entering the following commands.

RouterC(config)#interface ethernet 1/1

RouterC(config-if-e10000-1/1)#port-type customer-edge

RouterC(config-if-e10000-1/1)enable

RouterC(config-if-e10000-1/1)end

Provider Bridge Brocade1

1. Create the port-based VLAN that contains the tagged interface that you want to use by entering

the following commands.

Brocade1(config)# vlan30

Brocade1(config-vlan-30)# tagged ethe 1/1

2. Create the ESI Brocade1vlan300 as an encapsulated SVLAN with the ESI client Site1vlan30 by

entering the following commands.

Brocade1(config)#esi Brocade1vlan300 encapsulation svlan

Brocade1(config)#esi-client Site1vlan30

3. Add the port-based VLAN300 that contains the tagged interfaces that you want to use by

entering the following commands.

Brocade1(config)# vlan300

Brocade1(config-vlan-300)# tagged ethe 1/1 ethe 1/3

4. To enable CFM, enter the following command.

Brocade1(config)#cfm-enable

5. Create a maintenance domain with a specified name CUST_1 and level 5.