Provider bridge brocade2 – Brocade Multi-Service IronWare Administration Guide (Supporting R05.6.00) User Manual
Page 185

Multi-Service IronWare Administration Guide
167
53-1003028-02
CFM monitoring and show commands
6
Brocade1(config-cfm)#domain-name CUST_1 level 5
6. Create a maintenance association within a specified ESI Site1vlan30, and a vlan-id 30 with a
priority 3.
Brocade1(config-cfm-md-CUST_1)#ma-name ma_5 esi Site1vlan30 vlan-id 30
priority 3
7. Set the time interval between successive Continuity Check Messages to 10-seconds.
Brocade1(config-cfm-md-CUST_1-ma-ma_5)#ccm-interval 10-second
8. Configuring a MED for each of the Domain Service Access Points of a service instance creates
a MA to monitor the connectivity. Add ethernet port 1/2 as MEP to a specified maintenance
association.
Brocade1(config-cfm-md-CUST_1-ma-ma_5)#mep 4 up port ethe 1/2
9. To configure the hostname as Brocade1, enter a command such as the following.
Brocade1(config)#hostname Brocade1
10. Configure interface ethernet 1/1 as the provider network by entering the following commands.
Brocade1(config)#interface ethernet 1/1
Brocade1(config-if-e10000-1/1)#port-type provider-network
Brocade1(config-if-e10000-1/1)enable
Brocade1(config-if-e10000-1/1)end
11. Configure interface ethernet 1/2 as the customer-edge by entering the following commands.
Brocade1(config)#interface ethernet 1/2
Brocade1(config-if-e10000-1/2)#port-type custonmer-edge
Brocade1(config-if-e10000-1/2)enable
Brocade1(config-if-e10000-1/2)end
12. Configure interface ethernet 1/3 as the provider network by entering the following commands.
Brocade1(config)#interface ethernet 1/3
Brocade1(config-if-e10000-1/3)#port-type provider-network
Brocade1(config-if-e10000-1/3)enable
Brocade1(config-if-e10000-1/3)end
Provider Bridge Brocade2
1. Create the port-based VLAN300 that contains the tagged interfaces that you want to use by
entering the following commands.
Brocade2(config)# vlan300
Brocade2(config-vlan-300)# tagged ethe 1/1 ethe 1/3
2. To enable CFM, enter the following command.
Brocade2(config)#cfm-enable
3. Create a maintenance domain with a specified name CUST_1 and level 5.
Brocade2(config-cfm)#domain-name CUST_1 level 5
4. Create a maintenance association within a specified ESI Site2vlan30, and a vlan-id 30 with a
priority 3.
Brocade2(config-cfm-md-CUST_1)#ma-name ma_5 esi Site2vlan30 vlan-id 30
priority 3
5. Set the time interval between successive Continuity Check Messages to 10-seconds.