Multi-Service IronWare Administration Guide

53-1003028-02

CFM monitoring for ISID

6

Brocade_BEB_2(config)#interface ethernet 1/2

Brocade_BEB_2(config-if-e1000-1/2)#enable

Brocade_BEB_2(config-if-e1000-1/2)#port-type backbone-network

Brocade_BEB_2(config)#esi isid_1 encapsulation isid

Brocade_BEB_2(config-esi-isid_esi_1)#isid 2000

Brocade_BEB_2(config)# esi bvlan_1 encapsulation bvlan

Brocade_BEB_2(config-esi-bvlan_1)#vlan 200

Brocade_BEB_2(config-esi-bvlan_1-vlan-200)#tagged ethernet 1/2

Brocade_BEB_2(config-esi-bvlan_1)#esi-client isid_esi_1

Brocade_BCB(config)#tag-value tag1 88A8

Brocade_BCB(config)#interface ethernet 1/1

Brocade_BCB(config-if-e1000-1/1)#enable

Brocade_BCB(config)#interface ethernet 1/2

Brocade_BCB(config-if-e1000-1/2)#enable

Brocade_BCB(config)#vlan 200

Brocade_BCB(config-vlan-200)#tagged eth 1/1

Brocade_BCB(config-vlan-200)#tagged eth 1/2

Sample configuration for ISID CFM

The below configuration shows the sample configuration for ISID CFM

Brocade_BEB_1(config)#cfm-enable

Brocade_BEB_1(config-cfm)#domain-name ISID_domain level 7

Brocade_BEB_1(config-cfm-md-ISID_domain)#ma-name ISID_2000 esi isid_1 isid 2000

priority 7

Brocade_BEB_1(config-cfm-md-ISID_domain-ma-ISID_2000)#ccm-interval 1-second

Brocade_BEB_1(config-cfm-md-ISID_domain-ma-ISID_2000)#mep 1 down port eth 1/1

Brocade_BEB_1(config-cfm-md-ISID_domain-ma-ISID_2000)#

Brocade_BEB_2(config)#cfm-enable BEB_2(config-cfm)#domain-name ISID_domain level

7 Brocade_BEB_2(config-cfm-md-ISID_domain)#ma-name ISID_2000 esi isid_1 isid 2000

priority 7

Brocade_BEB_2(config-cfm-md-ISID_domain-ma-ISID_2000)#ccm-interval 1-second

Brocade_BEB_2(config-cfm-md-ISID_domain-ma-ISID_2000)#mep 2 down port eth 1/2

Brocade_BEB_2(config-cfm-md-ISID_domain-ma-ISID_2000)#

Show commands for CFM monitoring for ISID

The following show commands provide output for each component of the sample configuration.

Show cfm
Use the show cfm command to display the cfm configuration.

Syntax: show cfm

Brocade_BEB_1#show cfm

Domain: ISID_domain

Index: 1

Level: 3

Maintenance association: ISID_2000

Ma Index: 1

CCM interval: 1000 ms

ESI isid_1 ISID : 2000

Priority: 7

ETH-AIS TX: DISABLED