Brocade_BEB_2(config)#interface ethernet 1/2
Brocade_BEB_2(config-if-e1000-1/2)#enable
Brocade_BEB_2(config-if-e1000-1/2)#port-type backbone-network
Brocade_BEB_2(config)#esi isid_1 encapsulation isid
Brocade_BEB_2(config-esi-isid_esi_1)#isid 2000
Brocade_BEB_2(config)# esi bvlan_1 encapsulation bvlan
Brocade_BEB_2(config-esi-bvlan_1)#vlan 200
Brocade_BEB_2(config-esi-bvlan_1-vlan-200)#tagged ethernet 1/2
Brocade_BEB_2(config-esi-bvlan_1)#esi-client isid_esi_1
Brocade_BCB(config)#tag-value tag1 88A8
Brocade_BCB(config)#interface ethernet 1/1
Brocade_BCB(config-if-e1000-1/1)#enable
Brocade_BCB(config)#interface ethernet 1/2
Brocade_BCB(config-if-e1000-1/2)#enable
Brocade_BCB(config)#vlan 200
Brocade_BCB(config-vlan-200)#tagged eth 1/1
Brocade_BCB(config-vlan-200)#tagged eth 1/2
Sample configuration for ISID CFM
The below configuration shows the sample configuration for ISID CFM
Brocade_BEB_1(config)#cfm-enable
Brocade_BEB_1(config-cfm)#domain-name ISID_domain level 7
Brocade_BEB_1(config-cfm-md-ISID_domain)#ma-name ISID_2000 esi isid_1 isid 2000
priority 7
Brocade_BEB_1(config-cfm-md-ISID_domain-ma-ISID_2000)#ccm-interval 1-second
Brocade_BEB_1(config-cfm-md-ISID_domain-ma-ISID_2000)#mep 1 down port eth 1/1
Brocade_BEB_1(config-cfm-md-ISID_domain-ma-ISID_2000)#
Brocade_BEB_2(config)#cfm-enable BEB_2(config-cfm)#domain-name ISID_domain level
7 Brocade_BEB_2(config-cfm-md-ISID_domain)#ma-name ISID_2000 esi isid_1 isid 2000
priority 7
Brocade_BEB_2(config-cfm-md-ISID_domain-ma-ISID_2000)#ccm-interval 1-second
Brocade_BEB_2(config-cfm-md-ISID_domain-ma-ISID_2000)#mep 2 down port eth 1/2
Brocade_BEB_2(config-cfm-md-ISID_domain-ma-ISID_2000)#
Show commands for CFM monitoring for ISID
The following show commands provide output for each component of the sample configuration.
Show cfm
Use the show cfm command to display the cfm configuration.
Syntax: show cfm
Brocade_BEB_1#show cfm
Domain: ISID_domain
Index: 1
Level: 3
Maintenance association: ISID_2000
Ma Index: 1
CCM interval: 1000 ms
ESI isid_1 ISID : 2000
Priority: 7
ETH-AIS TX: DISABLED