beautypg.com

Np memory error monitoring, Np memory error monitoring overview, Np memory error monitoring: basic configuration – Brocade Multi-Service IronWare Administration Guide (Supporting R05.6.00) User Manual

Page 134

background image

116

Multi-Service IronWare Administration Guide

53-1003028-02

NP memory error monitoring

5

SYSLOG: <12>Feb 7 10:50:12 Ni-MLX-Sys-6 System: Low physical memory,

Pool(2-Global) below 10%, available pool memory (118108160), physical memory

(118108160) on MP

SYSLOG: <9>Feb 7 10:50:12 Ni-MLX-Sys-6 System: Low physical memory, Pool(2-Global)

below 5%, available pool memory (64421888), physical memory (64421888) on MP

SYSLOG: <10>Feb 7 10:50:12 Ni-MLX-Sys-6 System: Low pool memory, Pool(2-Global)

below 1%, available pool memory (28532736), physical memory (28532736) on MP

SYSLOG: <10>Feb 7 10:50:12 Ni-MLX-Sys-6 System: Low physical memory,

Pool(2-Global) below 1%, available pool memory (10731520), physical memory

(10731520) on MP

Clearing memory historgram data

To clear the memory histogram data, enter the following command:

Brocade(config)# clear memory histogram

Syntax: clear memory histogram

NP memory error monitoring

This sections discusses the following topics:

NP memory error monitoring overview

NP memory error monitoring: basic configuration

NP memory error monitoring overview

It can be useful to know when memory errors occur on interface modules. NP memory error
monitoring periodically monitors for external and internal memory errors and reports these errors
as syslog messages or generates SNMP traps.

For details of specific errors that may occur on interface cards that support NP memory error
monitoring, refer to

Appendix F, “NP Memory Errors”

.

NP memory error monitoring: basic configuration

By default:

NP memory error monitoring is enabled.

Errors generate both a syslog message and a SNMP trap.

The polling period time is 60 seconds.

Configuring NP memory error monitoring

You can configure:

The polling frequency.

How the errors are reported.

To set the polling frequency for NP memory errors at 10 second intervals, enter the following
command: