CFM monitoring and show commands

6

Brocade2(config-cfm-md-CUST_1-ma-ma_5)#ccm-interval 10-second

6. Configuring a MED for each of the Domain Service Access Points of a service instance creates

a MA to monitor the connectivity. Add ethernet port 1/2 as MEP to a specified maintenance
association.

Brocade2(config-cfm-md-CUST_1-ma-ma_5)#mep 5 up port ethe 1/2

7. To configure the hostname as Brocade1, enter a command such as the following.

Brocade2(config)#hostname Brocade1

8. Configure interface ethernet 1/1 as the provider network by entering the following commands.

Brocade2(config)#interface ethernet 1/1

Brocade2(config-if-e10000-1/1)#port-type provider-network

Brocade2(config-if-e10000-1/1)enable

Brocade2(config-if-e10000-1/1)end

9. Configure interface ethernet 1/2 as the customer-edge by entering the following commands.

Brocade2(config)#interface ethernet 1/2

Brocade2(config-if-e10000-1/2)#port-type custonmer-edge

Brocade2(config-if-e10000-1/2)enable

Brocade2(config-if-e10000-1/2)end

10. Configure interface ethernet 1/3 as the provider network by entering the following commands.

Brocade2(config)#interface ethernet 1/3

Brocade2(config-if-e10000-1/3)#port-type provider-network

Brocade2(config-if-e10000-1/3)enable

Brocade2(config-if-e10000-1/3)end

Provider Bridge Brocade3

1. Create the port-based VLAN that contains the tagged interface that you want to use by entering

the following commands.

Brocade3(config)# vlan30

Brocade3(config-vlan-30)# tagged ethe 1/2

2. Create the ESI Brocade3vlan300 as an encapsulated SVLAN with the ESI client Site3vlan30 by

entering the following commands.

Brocade3(config)#esi Brocade3vlan300 encapsulation svlan

Brocade3(config)#esi-client Site3vlan30

3. Add the port-based VLAN300 that contains the tagged interfaces that you want to use by

entering the following commands.

Brocade3(config)# vlan300

Brocade3(config-vlan-300)# tagged ethe 1/1 ethe 1/3

4. To enable CFM, enter the following command.

Brocade3(config)#cfm-enable

5. Create a maintenance domain with a specified name CUST_1 and level 5.

Brocade3(config-cfm)#domain-name CUST_1 level 5

6. Create a maintenance association within a specified ESI Site3vlan30, and a vlan-id 30 with a

priority 3.

Brocade3(config-cfm-md-CUST_1)#ma-name ma_5 esi Site3vlan30 vlan-id 30

priority 3