Displaying CFM configurations
The show cfm command, displays the current configuration and status of CFM. For the show cfm
command to take effect, CFM should first be enabled in Protocol Configuration mode.
Syntax: show cfm [domain name ] [ma ma-name]
The domain name parameter specifies a domain for display. By default, all defined domains are
shown.
The ma ma-name parameter specifies the maintenance association name. By default, all defined
domains are shown.
TABLE 28
Show CFM output descriptions
This field...
Displays...
Domain
The Domain is the network or the part of the network for which faults in connectivity
are displayed.
Index The
Domain
Index.
Level
The level is the domain level in the range 0-7. The levels can be:
•
Customer’s MD levels: 5 - 7
•
Provider’s MD levels: 3 - 4
•
Operator’s MD levels: 0 – 2
Maintenance Association
The maintenance association name.
Ma Index
The Maintenance Association Index.
CCM interval
The time interval between two successive Continuity Check messages (CCMs) that
are sent by MEPs in the specified Maintenance Domain.
VLAN ID
The VLAN identifier of the maintenance association.
VPLS ID
The VPLS identifier of the maintenance association.
Priority
The priority of the CCM messages, sent by MEPs, in the range 0-7.
MEP
The maintenance end point ID
Direction
DIsplays the direction the MEP was sent:
Up - The MEP direction away from the monitored VLAN.
Down - The MEP direction is towards the monitored VLAN.
MAC
DIsplays the associated MAC Address.
PORT
DIsplays the associated port.
Brocade#show cfm
Domain: md2
Index: 1
Level: 6
Maintenance association: ma2
Ma Index: 1
CCM interval: 10000 ms
VLAN ID: 2
Priority: 6
MEP Direction MAC PORT
==== ========= ========= ====
3 DOWN 0000.00f7.3831 ethe 2/2