beautypg.com

Display information, Defining remote failure actions, Forcing the efm-oam remote interface into loopback – Brocade Multi-Service IronWare Administration Guide (Supporting R05.6.00) User Manual

Page 212: Displaying oam information

background image

194

Multi-Service IronWare Administration Guide

53-1003028-02

IEEE 802.3ah EFM-OAM

6

Defining remote failure actions

By default, on receipt of a remote failure message, the device will only log the event. This can be
changed to block an interface on receipt of a remote failure message. The commands below
display the three events that the protocol supports.

Brocade(config-link-oam)#ethernet 2/1 remote-failure dying-gasp action

block-interface

Brocade(config-link-oam)#ethernet 2/1 remote-failure critical-event action

block-interface

Brocade(config-link-oam)#ethernet 2/1 remote-failure link-fault action

block-interface

Syntax: [no]ethernet slot/port remote-failure dying-gasp | link-fault | critical-event action

block-interface

The no form of the command returns to default state of logging.

Forcing the EFM-OAM remote interface into loopback

The link-oam remote-loopback ethernet slot/port start/stop command starts and stops the remote
loopback on the remote node.

Brocade# link-oam remote-loop-back ethernet 1/1 start

Syntax: [no]link-oam remote loopback ethernet slot/port start/stop

Display information

The following show commands will display OAM information.

DIsplaying OAM information

To show OAM information on all OAM enabled ports, enter a command such as the following:

Brocade#show link-oam info

Ethernet Link Status OAM Status Mode Local Stable Remote Stable

1/1 up up active satisfied satisfied

1/2 up up passive satisfied satisfied

1/3 up up active satisfied satisfied

1/4 up init passive unsatisfied unsatisfied

1/5 down down passive unsatisfied unsatisfied

1/6 down down passive unsatisfied unsatisfied

1/7 down down passive unsatisfied unsatisfied