Iscsi performance optimization, Iscsi storage, Iscsi luns – QNAP TVS-472XT 4-Bay NAS Enclosure User Manual

Page 376: Mapping a lun to an iscsi target

background image

3. Map the LUN to the iSCSI target.

Multiple LUNs can be mapped to one target.

For details, see

iSCSI LUN Actions

.

4. Install an iSCSI initiator application or driver on the host.

The host is the service, computer, or NAS device that will access the LUN.

5. Connect the iSCSI initiator to the iSCSI target on the NAS.

Warning

To prevent data corruption, multiple iSCSI initiators should not connect to the same LUN

simultaneously.

The LUNs mapped to the iSCSI target appear as disks on the host.

6. In the host OS, format the disks.

iSCSI Performance Optimization

You can optimize the performance of iSCSI by following one or more of these guidelines:

• Use thick provisioning (instant allocation). Thick provisioning gives slightly better read and write

performance than thin provisioning.

• Create multiple LUNs, one for each processor thread on the NAS. For example, if the NAS has four

processor threads, then you should create four or more LUNs.

Tip

Go to Control Panel > System > System Status > System Information > CPU to view the

number of processor threads.

• Use separate LUNs for different applications. For example, when creating two virtual machines which

intensively read and write data, you should create one LUN for each VM to distribute the load.

• You can use iSER (iSCSI Extensions for RDMA) for faster data transfers between QNAP NAS devices

and VMware ESXi servers. Enabling iSER requires a compatible network card and switch. For a list of

compatible network devices, see

https://www.qnap.com/solution/iser

.

iSCSI Storage

The iSCSI Storage screens allows you to view iSCSI targets. On this screen you can enable, disable, and edit

targets, view each target's mapped LUNs, edit LUN mappings, take snapshots of LUNs, and configure the

ISCSI access control list (ACL).

iSCSI LUNs

Mapping a LUN to an iSCSI Target

1. Go to iSCSI & Fibre Channel > iSCSI > iSCSI Storage .

2. Select a LUN.

Tip

Double-click an iSCSI target to view all of its mapped LUNs.

3. Optional: If the LUN is already mapped to a target, disable the LUN.

a. Click Action, and then select Disable

QTS 4.4.x User Guide

iSCSI & Fibre Channel

375