Rtd port number, Mac address, Pro software & meet manager enable – Daktronics OmniSport 2000 Timing Console User Manual
Page 80

62
Swimming Mode Menus & Settings
MENU-NETWORK
5-RTD PORT #
1-DVX/N 2-GALXY*
PORT#- 3002
1
CUSTOM
PORT#- 18000*
MENU-NETWORK
7-NETWK PRO/MMR
MENU-NETWORK
6-MAC ADDRESS
RTD Port Number
This menu allows the operator to set or verify the RTD port
number of the console. The default setting is shown below.
In most cases, the standard RTD port number
should be selected. Press [1].
o
If the RTD will be sent to a Daktronics DVX/N video
display, press [1] followed by [ENTER]. The standard
port number will vary by console name as shown in
the table at right.
o
If the RTD will be sent to a Daktronics Galaxy
message center, press [2] followed by [ENTER]. The
standard port number will always be “3002”.
If a custom RTD port number is required, press [2].
Press the [0]-[9] keys to enter a new value and press
[ENTER]. To select a standard port number
instead, press [CLEAR] twice to exit the menu.
MAC Address
This menu allows the operator to verify the MAC address
of the console. The MAC Address cannot be edited. Press
any key to exit the menu.
Pro Software & Meet Manager Enable
This menu allows the operator to enable network
communications to Pro Swimming and Meet Manager
(results) software.
Use [←][→] to toggle between ON/OFF and then press [ENTER] to continue.
Use [←][→] to toggle between ON/OFF and then press [ENTER] to save.
Name
RTD Port #
OMNI1 21000
OMNI2 21001
OMNI3 21002
OMNI4 21003
From Main Menu
– [4]>[7]>[5]
1-STD* 2-CUST
PORT#- 3002
1
From Main Menu
– [4]>[7]>[7]
MENU-NETWORK
NETWORK PRO:ON *
MENU-NETWORK
NETWORK MMR:ON *
MAC ADDRESS
09:ec:03:01:06
From Main Menu
– [4]>[7]>[6]