Swimming Mode Menus & Settings

51

MENU-TI MER
5-ARMI NG DELAY

MENU-TI MER
6-PRECI SI ON

MENU-TI MER
7-RELAY TAKE-OFF

RELAY TAKE-OFF
BTN/DAKTRONI CS *

If the discrepancy exceeds the flag time, the timer places an asterisk (*) next to that touchpad
time on the final results. Most rules say that if the touchpad time and the back-up time are
more than 0.3 seconds, they need to be reviewed. The flag time can be set from 0.0 to 0.9
seconds. If it is set to 0.0, the console will not flag discrepancies.

Press the [0]-[9] keys to enter the flag time and then press [ENTER] to save.

Arming Delay

This menu determines the length of time (Arming Delay)
that the touchpad will be inactive following a split time.





This function is extremely useful during relay exchanges to provide enough time for the
athlete to exit the pool. The delay can be set from 1 to 99 seconds. Fifteen to 20 seconds is a
typical setting, depending on the caliber of the athlete and the length of the pool.

Press the [0]-[9] keys to enter the arming delay time and then press [ENTER] to save.

Precision

The OmniSport 2000 console is an extremely accurate
timing device. This menu tells the timer if it should report
and display the times to one hundredth (1/100) or one
thousandth (1/1000) of a second. All of the rule books say
that the system should time to 1/100 of a second.



Use [←][→] to toggle the setting between 1/100 or 1/1000 and then press [ENTER] to save.

Relay Take-Off

This group of menus will configure whether Relay Take-Off
Platforms are connected to the console, or if only push
buttons are being used.

If the console is set to use platforms or a button, the console will also ask which button input
they will be plugged into on the lane module or deck plate and the arm time that configures
how long the console is comparing the touchpad to the platform. For more information about
Relay Take-Off Platforms, refer to Section 12.

The console can be set to NONE, BTN/DAKTRONICS, or
OMEGA PLATFORM
. NONE tells the timer that there are
no platforms connected. BTN/DAKTRONICS tells the timer
that a push button or a Daktronics RTOP is connected.