RTD Output Specifications
227
Appendix D: RTD Output Specifications
This appendix contains Real-Time Data (RTD) output specifications. Input Template Files (ITFs) may
be downloaded here:
Serial Port (COM) Transmission Specifications
Baud Rate: 19,200
Parity: None
Data Bits: 8
Protocol: Enhanced
Size: 4096
Swimming (OS2-Swimming.itf)
Field #
Function
Length
Justification
Item Number
1
Running time
9
L
1
2
Event title line 1
30
L
10
3
Event title line 2
30
L
40
4
Event title lines 1 & 2
30
L
70
5
Event number
3
R
100
6
Event number-Alpha
1
L
103
7
Heat number
2
R
104
8
Heat number-Alpha
20
L
106
9
Round number
1
L
126
10
Maximum lengths to complete
2
R
127
11
Lengths completed
2
R
129
12
Record 1 name
12
L
131
13
Record 1 code
2
L
143
14
Record 1 time
9
L
145
15
Record 2 name
12
L
154
16
Record 2 code
2
L
166
17
Record 2 time
9
L
168
18
Record 3 name
12
L
177
19
Record 3 code
2
L
189
20
Record 3 time
9
L
191
21
Record 4 name
12
L
200
22
Record 4 code
2
L
212
23
Record 4 time
9
L
214
24
Line 1 swimmer name
15
L
223
25
Line 1 team name
5
L
238
26
Line 1 lane number
2
R
243
27
Line 1 place number
3
R
245
28
Line 1 split/finish time
9
L
248
29
Line 1 lengths completed
2
R
257