• Configuration Revision
The revision of the MSTI configuration named above. This must be an integer
between 0 and 65535.
MSTI Mapping
Object
Description
• MSTI
The bridge instance. The CIST is not available for explicit mapping, as it will
receive the VLANs not explicitly mapped.
• VLANs Mapped
The list of VLAN's mapped to the MSTI. The VLANs must be separated with
comma and/or space. A VLAN can only be mapped to one MSTI. A unused MSTI
should just be left empty. (I.e. not having any VLANs mapped to it.)
Buttons
: Click to save changes.
: Click to undo any changes made locally and revert to previously saved values.
MSTI Ports Configuration
This page allows the user to inspect the current STP MSTI port configurations, and possibly change them as well.
A MSTI port is a virtual port, which is instantiated separately for each active CIST (physical) port for each MSTI instance configured
and applicable for the port. The MSTI instance must be selected before displaying actual MSTI port configuration options.
This page contains MSTI port settings for physical and aggregated ports. The aggregation settings are stack global. The MSTI Port
Configuration screen is shown
Figure 4-7-12
&
Figure 4-7-13.
Figure 4-7-12
MSTI Port Configuration page screenshot
The page includes the following fields:
MSTI Port Configuration
Object
Description
• Select MSTI
Select the bridge instance and set more detail configuration.