beautypg.com

Interlogix GE-DSSG-244-POE User Manual User Manual

Page 109

background image

IFS NS3601-24P/4S GE-DSSG-244 and 244-POE User Manual

107

„

Untagged packet entering VLAN 3

1. While

[PC-4]

transmit an untagged packet enters Port-4, the switch will tag it with a VLAN Tag=3. [PC-5] and [PC-6]

will received the packet through Port-5 and Port-6.

2.

While the packet leaves Port-5, it will be stripped away it tag becoming an untagged packet.

3.

While the packet leaves Port-6, it will keep as a tagged packet with VLAN Tag=3.

At this example, VLAN Group 1 just set as default VLAN, but only focus on VLAN 2 and VLAN 3 traffic
flow

Setup steps

1. Create

VLAN

Group

Set VLAN Group 1 = Default-VLAN with VID (VLAN ID) =1
Add two VLANs – VLAN 2 and VLAN 3

VLAN Group 2 with VID=2
VLAN Group 3 with VID=3

2. Assign VLAN Member :

VLAN 2 : Port-1,Port-2 and Port-3
VLAN 3 : Port-4, Port-5 and Port-6
VLAN 1 : All other ports – Port-7~Port-24

3. Remove VLAN Member for VLAN 1:

Remember to remove the Port 1 – Port 6 from VLAN 1 membership, since the Port 1 – Port 6 had be assigned to VLAN 2 and
VLAN 3.

Figure 4-6-9

Add new VLAN group, assign VLAN members for VLAN 2 and VLAN 3 and remove specify ports from VLAN 1 member

It’s import to remove the VLAN members from VLAN 1 configuration. Or the ports would become
overlap setting. ( About the overlapped VLAN configuration, see next VLAN configure sample)

4. Assign PVID for each port:

Port-1,Port-2 and Port-3 : PVID=2
Port-4,Port-5 and Port-6 : PVID=3
Port-7~Port-24 : PVID=1

5. Enable VLAN Tag for specific ports

Link Type : Port-3 (VLAN-2) and Port-6 (VLAN-3)

This manual is related to the following products: