Interlogix 600-1053-4 User Manual
Interlogix Accessories communication
P/N 466-xxxx4429
• REV B • 08Jul13
1
600-1053-4 Concord 4 Cellular Module
Installation Sheet
Part Number
Description
600-1053-4-ZX-AT
Concord Cellular Module, Alarm.com
HSPA 3G GSM with Z-wave, AT&T
600-1053-4-ZX-RG
Concord Cellular Module, Alarm.com
HSPA 3G GSM with Z-wave, Rogers
(Canada use only)
600-1053-4-ZX-TM
Concord Cellular Module, Alarm.com
HSPA 3G GSM with Z-wave, T-Mobile
600-1053-4-ZX-VZ
Concord Cellular Module, Alarm.com
HSPA 3G CDMA with Z-wave, Verizon
Description
The cellular module interfaces with the Concord panel data bus
and is powered by the panel battery or an auxiliary 12 VDC
power supply. The module can be used on Concord 4.0 and
higher. Status LEDs indicate bus and cellular network
communications. A supervised zone input allows you to
connect a hard-wired contact.
Figure 1 below shows the location of the main module
components and Table 1 below describes the component
functions.
Figure 1: Components
Table 1: Components
Component
Function
PWR LED
Indicates module power status.
BUS LED
Indicates data bus activity between the
panel and module.
AUTO LED
Indicates module/data transceiver
communication.
Status LEDs
Indicates communication status with cellular
network.
Wiring terminals
Provides panel and zone wiring connections.
Antenna connector
Antenna connection for snap-in MMCX
antenna.
Cellular status LEDs
Indicates communication with the cellular
network, report errors, and signal strength.
Serial number
A 15-digit number. Only the last 10 digits
(after the dash “-“) are used for account
activation.
Use the following tips to ensure success with the Alarm.com
Concord cellular module:
•
Make sure you create the customer account on the
Alarm.com dealer website at least 24 hours before
installation.
•
Make sure you turn off the Access Code Lock feature.
Note: This feature must be off for the system to
communicate with Alarm.com
•
Use the LEDs on the module to check the signal strength
before you permanently mount the module.
•
Power the module off the battery, not off the panel.
•
Do a manual phone test to initiate communication (see
“Power up” on page 4).
Account creation
Before installing the Alarm.com cellular module in a Concord
system, a new customer account needs to be created with
Alarm.com. We recommend creating the account at least 24