IFS NS3601-24P/4S GE-DSSG-244 and 244-POE User Manual

103

For private VLANs to be applied, the switch must first be configured for standard VLAN operation When this is in place, one or
more of the configured VLANs can be configured as private VLANs. Ports in a private VLAN fall into one of these two groups:

„

Promiscuous ports

— Ports from which traffic can be forwarded to all ports in the private VLAN
— Ports which can receive traffic from all ports in the private VLAN

„

Isolated ports

— Ports from which traffic can only be forwarded to promiscuous ports in the private VLAN
— Ports which can receive traffic from only promiscuous ports in the private VLAN

The configuration of promiscuous and isolated ports applies to all private VLANs. When traffic comes in on a promiscuous port in a
private VLAN, the VLAN mask from the VLAN table is applied. When traffic comes in on an isolated port, the private VLAN mask is
applied in addition to the VLAN mask from the VLAN table. This reduces the ports to which forwarding can be done to just the
promiscuous ports within the private VLAN.

The port settings relate to the currently selected stack unit, as reflected by the page header. This feature works across the stack.
The Port Isolation Configuration screen is shown

Figure 4-6-6

.