Port isolate – Interlogix GE-DSSG-244-POE User Manual User Manual
Page 112
IFS NS3601-24P/4S GE-DSSG-244 and 244-POE User Manual
110
4. Assign the VLAN Trunk Port to be the member of each VLAN – which wants to be aggregated. At this sample, add Port-8 to be
VLAN 2
and VLAN 3 member port. The screen is shown
Figure 4-6-12.
5.
Figure 4-6-12
VLAN overlap port setting & VLAN 1 – The public area member assign
6. Specify
Port-8
to be the 802.1Q VLAN Trunk port, and the Trunking port must be a Tagged port while egress. The Port-8
configuration as the following screen is shown
Figure 4-6-1
3
.
Figure 4-6-13
The configuration of VLAN Trunk port
That is, although the VLAN 2 members: Port-1 to Port-3 and VLAN 3 members: Port-4 to Port-6 also belongs to VLAN 1. But with
different PVID settings, packets form VLAN 2 or VLAN 3 is not able to access to the other VLAN.
7. Repeat Step 1 to 5, setup the VLAN Trunk port at the partner switch and add more VLANs to join the VLAN trunk, repeat Step 1
to 3 to assign the Trunk port to the VLANs.
Port Isolate
The diagram shows how the Managed Switch handles isolate and promiscuous ports, and the each PCs are not able to access each
other PCs of each isolate port. But they all need to access with the same server/AP/Printer. The screen is shown
Figure 4-6-14
. This
section will show you how to configure the port for the server – that could be accessed by each isolate port.