[Pr - 6.08]

Fault Detail Data Selection 2

Ultraware Name

Fault Detail Setup: Channel B

Description

Refer to Monitor Variables on page 131

for more

information on the range options.

Range

0…28
(except 15, 23, 25, and 26)

Default

3

When Enabled

Immediately (ENG Mode)

[Pr - 6.09]

Fault Detail Data Selection 3

Ultraware Name

Fault Detail Setup: Channel C

Description

Refer to Monitor Variables on page 131

for more

information on the range options.

Range

0…28
(except 15, 23, 25, and 26)

Default

11

When Enabled

Immediately (ENG Mode)

[Pr - 6.10]

Fault Detail Data Selection 4

Ultraware Name

Fault Detail Setup: Channel D

Description

Refer to Monitor Variables on page 131

for more

information on the range options.

Range

0…28
(except 15, 23, 25, and 26)

Default

16

When Enabled

Immediately (ENG Mode)

[Pr - 6.11]

1st Resonant Frequency Suppression Filter

Ultraware Name

Main Current Regulator Gains: 1st Resonant Frequency
Suppression Filter

Description

Suppresses Vibration by cutting off Current Command in
assigned frequency band

Range

0…10,000

Default

10,000

Units

Hz

When Enabled

Immediately (Read Parameter for ENG)

Applicable Operating Mode

All