10], fault detail data selection 4 – Rockwell Automation 2071-Axx Kinetix 3 Component Servo Drive Serial Host Command Reference Manual User Manual
Page 99

Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
99
Standard Drive Parameters
Appendix A
[Pr - 6.08]
Fault Detail Data Selection 2
Ultraware Name
Fault Detail Setup: Channel B
Description
Refer to Monitor Variables on page 131
for more
information on the range options.
Range
0…28
(except 15, 23, 25, and 26)
Default
3
When Enabled
Immediately (ENG Mode)
[Pr - 6.09]
Fault Detail Data Selection 3
Ultraware Name
Fault Detail Setup: Channel C
Description
Refer to Monitor Variables on page 131
for more
information on the range options.
Range
0…28
(except 15, 23, 25, and 26)
Default
11
When Enabled
Immediately (ENG Mode)
[Pr - 6.10]
Fault Detail Data Selection 4
Ultraware Name
Fault Detail Setup: Channel D
Description
Refer to Monitor Variables on page 131
for more
information on the range options.
Range
0…28
(except 15, 23, 25, and 26)
Default
16
When Enabled
Immediately (ENG Mode)
[Pr - 6.11]
1st Resonant Frequency Suppression Filter
Ultraware Name
Main Current Regulator Gains: 1st Resonant Frequency
Suppression Filter
Description
Suppresses Vibration by cutting off Current Command in
assigned frequency band
Range
0…10,000
Default
10,000
Units
Hz
When Enabled
Immediately (Read Parameter for ENG)
Applicable Operating Mode
All