Parameter descriptions, Group 0 - indexing system, In00.02 – Rockwell Automation 2071-Axx Kinetix 3 Component Servo Drive Serial Host Command Reference Manual User Manual
Page 114

114
Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
Appendix B
Indexing Drive Parameters
Parameter Descriptions
Parameter descriptions list the size of each parameter and the data options within
the parameter.
Descriptions for Standard Drive Parameters begin on
Group 0 - Indexing System
[IN00.00]
Auto Start Indexing
Ultraware Name
Auto Start Indexing
Description
When this field is set to ON, the drive begins executing the
selected index whenever the drive enables.
Range Value
Description
0
OFF
1
ON
Default 0
Units N/A
Access Set
Changeable Status
Always
When Enabled
Power Cycling
Applicable Operating Mode
Indexing
Modbus Address
5000
[IN00.01]
Abort Index Deceleration
Ultraware Name
Abort Index Decel
Description
The deceleration used to stop motion when the Stop
Index input terminates an index move.
Range Value
Description
1 …2,147,483,647
10
-2
* rev/s
2
for rotary,
mm/s
2
for linear
Default 6250
Access Set
Changeable Status
Always
When Enabled
Power Cycling
Applicable Operating Mode
Indexing
Modbus Address
5001...5002
[IN00.02]
Positive Deceleration Distance
Ultraware Name
Positive Deceleration Distance
Range Value
Description
0 …2,147,483,647
The stopping distance used
when the drive encounters
a positive overtravel limit.
Default 0