[IN01.09] Home

Current

Ultraware Name

Home Current

Description

Specifies the torque feedback at which the drive stops
moving the motor at the Homing Velocity.

Range Value

Description

1 …250

Percent of motor torque
feedback

Default 100

Units

Percentage of a motor rating torque

Access Set

Changeable Status

Disable Drive

When Enabled

Disable Drive

Applicable Operating Mode

Indexing

Modbus Address

5213

[IN01.10]

Home Current Time

Ultraware Name

Home Current Time

Description

Specifies the time interval that the home current must be
held.

Range Value

Description

0 …1000

ms

Default 0

Units Milliseconds

Access Set

Changeable Status

Disable Drive

When Enabled

Disable Drive

Applicable Operating Mode

Indexing

Modbus Address

5214