Indexing Drive Parameters
[IN01.09] Home
Current
Ultraware Name
Home Current
Description
Specifies the torque feedback at which the drive stops
moving the motor at the Homing Velocity.
Range Value
Description
1 …250
Percent of motor torque
feedback
Default 100
Units
Percentage of a motor rating torque
Access Set
Changeable Status
Disable Drive
When Enabled
Disable Drive
Applicable Operating Mode
Indexing
Modbus Address
5213
[IN01.10]
Home Current Time
Ultraware Name
Home Current Time
Description
Specifies the time interval that the home current must be
held.
Range Value
Description
0 …1000
ms
Default 0
Units Milliseconds
Access Set
Changeable Status
Disable Drive
When Enabled
Disable Drive
Applicable Operating Mode
Indexing
Modbus Address
5214