beautypg.com

Rockwell Automation 2071-Axx Kinetix 3 Component Servo Drive Serial Host Command Reference Manual User Manual

Page 89

background image

Rockwell Automation Publication 2071-RM001B-EN-P - April 2013

89

Standard Drive Parameters

Appendix A

[Pr - 3.08]

Digital Filter Cut-off Frequency

Data Size

3 digits

Digit 0

Low drive input

Value

Description

0x0 …0x7

0: 3 MHz

1: 1.75 MHz

2: 1.5 MHz

3: 1 MHz

4: 0.75 MHz

5: 0.625 MHz

6: 0.562 MHz

7: 0.525 MHz

Default = 1

Digit 1

Open collector input

Value

Description

0x0 …0x7

0: 3 MHz

1: 1.75 MHz

2: 1.5 MHz

3: 1 MHz

4: 0.75 MHz

5: 0.625 MHz

6: 0.562 MHz

7: 0.525 MHz

Default = 5

Digit 2

High frequency line drive input

0x0 …0x7

0: 3 MHz

1: 1.75 MHz

2: 1.5 MHz

3: 1 MHz

4: 0.75 MHz

5: 0.625 MHz

6: 0.562 MHz

7: 0.525 MHz

Default = 0

When Enabled

Servo-Off -> Setting

Applicable Operating Mode

All

Modbus Address

308