Standard Drive Parameters
Appendix A
[Pr - 0.11]
Allocation of Input Signals 2
Range for all digits
0…B, where 0 is Off, B is On and 1…A are digital inputs
Data Size
4 digits
Digit
Description
Default
Unmapped IO
Status
0
Fault reset (A-RST)
0x5
OFF
1
Negative current limit (N-TL)
0x6
OFF
2
Positive current limit (P-TL)
0x7
OFF
3
Operation mode override (C-SEL)
0x0
OFF
When Enabled
Servo-Off -> Setting
(1)
(1)
Refer to Setting Values for Parameters [Pr - 0.10]…[Pr - 0.21] on page 61
.
Applicable Operating Mode
All
Modbus Address
[Pr - 0.12]
Allocation of Input Signals 3
Range for all digits
0…B, where 0 is Off, B is On and 1…A are digital inputs
Data Size
4 digits
Digit
Description
Default
Unmapped IO
Status
0
Preset direction (C-DIR)
0x0
OFF
1
Preset select 1 (C-SP1)
0x0
OFF
2
Preset select 2 (C-SP2)
0x0
OFF
3
Preset select 3 (C-SP3)
0x0
OFF
When Enabled
Servo-Off -> Setting
(1)
(1)
Refer to Setting Values for Parameters [Pr - 0.10]…[Pr - 0.21] on page 61
.
Applicable Operating Mode
All
Modbus Address