Modbus Protocol

Chapter 1

Save Parameters

When the Standard and Indexing parameters are written by using function code
0x06, their values are stored to the volatile RAM temporarily and are lost after
powering off. To permanently store the parameters values in the nonvolatile flash
memory, write a 1 to the address 9999, by using the function code 0x06, 0x10.

IMPORTANT

Nonvolatile memory is limited to 100,000 erase/program cycles.

Modbus Address

Data Status Description

9999 (decimal)

1

Write data into nonvolatile memory