Appendix B
Indexing Drive Parameters
Group 2 - Indexing Options
[IN02.00] …[IN02.63] Index
0…63 Type and Action When Complete
Description
Digit 0 homes the axis, and digit 2 controls execution of
the index move command.
Digit 0
Homes the axis before the drive can executes any index.
Ultraware Name
Index 0…63 Option: Type
Range
Value
Description
0
Absolute: moves from its
starting position to the
specified Position, below.
1
Incremental: moves from
its starting position the
specified Distance, below.
Default
1
Digit 1
Controls execution of the index move command after
homing.
Ultraware Name
Index 0…63 Action When Complete
Range
Value
Description
0
Stop: ends the execution of
indexed move commands.
1 Start
next
index:
commands execution of
the Next Index move
without additional input,
but after the scheduled
Dwell.
2
Wait for Start: commands
execution of the Next Index
move the next time the
Start Index input becomes
active.
Default
0
Access Set
Changeable Status
Always
When Enabled
Always
Applicable Operating Mode
Indexing
Modbus Address
5400 …5463