Rockwell Automation 2071-Axx Kinetix 3 Component Servo Drive Serial Host Command Reference Manual User Manual
Page 69

Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
69
Standard Drive Parameters
Appendix A
[Pr - 1.07]
Current Command Lowpass Filter Bandwidth
Ultraware Name
Main Current Regulator Gains: Low Pass Filter Bandwidth
Range
0…10,000
Default
300
Units
Hz
Applicable Operating Mode
All
When Enabled
Immediately
When Enabled
Immediately
Applicable Operating Mode
All
Modbus Address
[Pr - 1.08]
Velocity Command Lowpass Filter Bandwidth
Ultraware Name
Main Velocity Regulator Gains: Low Pass Filter Bandwidth
Range
0…10,000
Default
1000
Units
Hz
When Enabled
Immediately
Applicable Operating Mode
Follower, Analog Speed, Preset
Modbus Address
[Pr - 1.09]
Position Command Lowpass Filter Bandwidth
Ultraware Name
Main Position Regulator Gains: Low Pass Filter Bandwidth
Range
0…1000
Default
0
Units
Hz
When Enabled
Immediately
Applicable Operating Mode
Follower
Modbus Address
[Pr - 1.10]
1st Resonant Frequency Suppression Filter
Ultraware Name
Main Current Regulator Gains: 1st Resonant Frequency
Suppression Filter
Description
Suppresses Vibration by cutting off Current Command in
assigned frequency band
Range
0…10,000
Default
10,000
Units
Hz
When Enabled
Immediately
Applicable Operating Mode
All
Modbus Address