Parameter descriptions, Group 0 - system level, Pr - 0.00], operations mode on – Rockwell Automation 2071-Axx Kinetix 3 Component Servo Drive Serial Host Command Reference Manual User Manual
Page 48

48
Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
Appendix A
Standard Drive Parameters
Parameter Descriptions
Parameter descriptions list the size of each parameter and the data options within
the parameter.
Descriptions of Indexing Drive Parameters begin on
Group 0 - System Level
[Pr - 0.00]
Operations Mode
Ultraware Name
Operation Modes (Main/Override)
Range 1…12
Display (Value)
Normal operating mode
Override operating mode
F (1) Follower
Follower
S (2)
Analog Velocity Input
Analog Velocity Input
C (3)
Analog Current Input
Analog Current Input
SF (4) Analog
Velocity
Input
Follower
CF (5)
Analog Current Input
Follower
CS (6)
Analog Current Input
Analog Velocity Input
P (7)
Preset Velocity
Preset Velocity
PF (8) Preset
Velocity
Follower
PS (9)
Preset Velocity
Analog Velocity Input
PC (10)
Preset Velocity
Analog Current Input
D (11) Reserved
Reserved
I (12) Indexing
Indexing
Default 1
When Enabled
Servo-Off -> Setting -> After power cycle
Applicable Operating Mode
All
Modbus Address
[Pr - 0.01]
Reserved
Reserved for future use.