[Pr - 5.00]
In Position Size
Ultraware Name
Position Functions: In Position Size
Description
If position error < In Position Size for 1 ms and the In
Position Size output signal is assigned, the In Position
output is turned ON.
Range
0…2500
Default
10
Units
Counts
When Enabled
Immediately
Applicable Operating Mode
Follower
Modbus Address
[Pr - 5.01]
Reserved
When Enabled
Reserved for future use.
[Pr - 5.02]
Near Position Size
Ultraware Name
Position Functions: Near Position Size
Description
If position error < Near Position Size and the Near Position
output signal is assigned, the Near Position output is
turned ON
Range
0…2500
Default
20
Units
Counts
When Enabled
Immediately
Applicable Operating Mode
Follower
Modbus Address