Rockwell Automation 2071-Axx Kinetix 3 Component Servo Drive Serial Host Command Reference Manual User Manual

Page 120

background image

120

Rockwell Automation Publication 2071-RM001B-EN-P - April 2013

Appendix B

Indexing Drive Parameters

[IN01.05] Offset

Move

Distance

Ultraware Name

Offset Move Distance

Description

The distance the motor position is from the marker edge
after the homing sequence is complete.
For Sensor Only Homing, the distance the motor position
is from the sensor edge after the homing sequence is
complete.

Range Value

Description

-2,147,483,647
…2,147,483,647

Digital input state
communicated to the drive
when the Home Sensor
input becomes active.

Default 0

Units Counts

Access Set

Changeable Status

Disable Drive

When Enabled

Disable Drive

Applicable Operating Mode

Indexing

Modbus Address

5206 …5207

[IN01.06]

Home Sensor Polarity

Ultraware Name

Home Sensor Polarity

Description Specifies

the digital input state communicated to the

drive when the Home Sensor input becomes active.

Range Value

Description

0 Active-Going

Transition

1

Inactive-Going Transition

Default 0

Units Counts

Access Set

Changeable Status

Disable Drive

When Enabled

Disable Drive

Applicable Operating Mode

Indexing

Modbus Address

5208