Standard Drive Parameters

[Pr - 1.11]

1st Resonant Frequency Suppression Filter Width

Ultraware Name

Main Current Regulator Gains: 1st Resonant Frequency
Suppression Filter Width

Description

Set up the notch width of 1st resonance suppressing filter
in 20 steps. Higher the setup, larger the notch width you
can obtain.

Range

1…20

Default

10

Units

When Enabled

Immediately

Applicable Operating Mode

All

Modbus Address

111

[Pr - 1.12]

2nd Resonant Frequency Suppression Filter

Ultraware Name

2nd Main Current Regulator Gains: 2nd Resonant
Frequency Suppression Filter

Description

Suppresses Vibration by cutting off Current Command in
assigned frequency band

Range

0…10,000

Default

10,000

Units

Hz

When Enabled

Immediately

Applicable Operating Mode

All

Modbus Address

112

[Pr - 1.13]

2nd Resonant Frequency Suppression Filter Width

Ultraware Name

Main Current Regulator Gains: 2nd Resonant Frequency
Suppression Filter Width

Description

Set up the notch width of 2nd resonance suppressing
filter in 20 steps. The higher the setup, larger the notch
width you can obtain.

Range

1…20

Default

10

Units

-

When Enabled

Immediately

Applicable Operating Mode

All

Modbus Address

113