115
Indexing Drive Parameters
Appendix B
Units Counts
Access Set
Changeable Status
Always
When Enabled
Always
Applicable Operating Mode
Indexing
Modbus Address
5003...5004
[IN00.03]
Negative Deceleration Distance
Ultraware Name
Negative Deceleration Distance
Range Value
Description
0 …2,147,483,647
The stopping distance used
when the drive encounters
a negative overtravel limit.
Default 0
Units Counts
Access Set
Changeable Status
Always
When Enabled
Always
Applicable Operating Mode
Indexing
Ultraware Name
Positive Deceleration Distance
Modbus Address
5005...5006
[IN00.04] Enable
Software
Limits
Ultraware Name
Enable Software Limits
Description
Controls software overtravel limits of the axis.
Range Value
Description
0
Off: Turns off software
overtravel limit checking.
1
On: Causes the drive to
compare the motor
feedback position to the
Positive and Negative
Software Limits, below, to
determine if the drive has
exceeded an overtravel
limit.
Default 0
Units N/A
Access Set
Changeable Status
Disable Drive
When Enabled
Disable Drive
Applicable Operating Mode
Indexing
Modbus Address
5007
[IN00.02]
Positive Deceleration Distance (continued)