Group 6 - supplemental gain and report settings, Analog velocity command offset, Analog current command offset – Rockwell Automation 2071-Axx Kinetix 3 Component Servo Drive Serial Host Command Reference Manual User Manual
Page 97: U phase current sensing offset, W phase current sensing offset

Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
97
Standard Drive Parameters
Appendix A
Group 6 - Supplemental Gain and Report Settings
[Pr - 6.00]
Analog Velocity Command Offset
Ultraware Name
Velocity Command Offset
Range
-10,000…10,000
Default
0
Units
0.1 mV
When Enabled
Servo-Off -> Setting (ENG Mode)
Applicable Operating Mode
Analog Velocity Command
[Pr - 6.01]
Analog Current Command Offset
Ultraware Name
Current Command Offset
Range
-10,000…10,000
Default
0
Units
0.1 mV
When Enabled
Servo-Off -> Setting (ENG Mode)
Applicable Operating Mode
Analog Current Command
[Pr - 6.02]
U Phase Current Sensing Offset
Ultraware Name
Calibration: U Phase Current Offset
Range
-60,000…60,000
Default
0
Units
0.01 mA
When Enabled
Servo-Off -> Setting (ENG Mode)
Applicable Operating Mode
All
[Pr - 6.03]
W Phase Current Sensing Offset
Ultraware Name
Calibration: W Phase Current Offset
Range
-60,000…60,000
Default
0
Units
0.01 mA
When Enabled
Servo-Off -> Setting (ENG Mode)
Applicable Operating Mode
All
[Pr - 6.04]
A lead B Swap
Ultraware Name
A lead B Swap
Description
Select A-lead-B, or B-lead-A
Data Size
1 digit