Group 6 - Supplemental Gain and Report Settings

[Pr - 6.00]

Analog Velocity Command Offset

Ultraware Name

Velocity Command Offset

Range

-10,000…10,000

Default

0

Units

0.1 mV

When Enabled

Servo-Off -> Setting (ENG Mode)

Applicable Operating Mode

Analog Velocity Command

[Pr - 6.01]

Analog Current Command Offset

Ultraware Name

Current Command Offset

Range

-10,000…10,000

Default

0

Units

0.1 mV

When Enabled

Servo-Off -> Setting (ENG Mode)

Applicable Operating Mode

Analog Current Command

[Pr - 6.02]

U Phase Current Sensing Offset

Ultraware Name

Calibration: U Phase Current Offset

Range

-60,000…60,000

Default

0

Units

0.01 mA

When Enabled

Servo-Off -> Setting (ENG Mode)

Applicable Operating Mode

All

[Pr - 6.03]

W Phase Current Sensing Offset

Ultraware Name

Calibration: W Phase Current Offset

Range

-60,000…60,000

Default

0

Units

0.01 mA

When Enabled

Servo-Off -> Setting (ENG Mode)

Applicable Operating Mode

All

[Pr - 6.04]

A lead B Swap

Ultraware Name

A lead B Swap

Description

Select A-lead-B, or B-lead-A

Data Size

1 digit