Rockwell Automation Publication 2071-RM001B-EN-P - April 2013

121

Indexing Drive Parameters

Appendix B

[IN01.07] Home

Position

Ultraware Name

Home Position

Description

The home position when a homing procedure is
completed.

Range Value

Description

-2,147,483,647
…2,147,483,647

Digital input of the home
position.

Default 0

Units Counts

Access Set

Changeable Status

Disable Drive

When Enabled

Disable Drive

Applicable Operating Mode

Indexing

Modbus Address

5209 …5210

[IN01.08]

Moving Distance After Home Sensor

Ultraware Name

Moving Distance After Home Sensor

Description

This value is distance that the drive ignores the marker
inputs after the home sensor is detected.

Range Value

Description

0 …2,147,483,647

Distance the drive ignores
the marker inputs after
home is detected.

Default 0

Units Counts

Access Set

Changeable Status

Disable Drive

When Enabled

Disable Drive

Applicable Operating Mode

Indexing

Modbus Address

5211 …5212