Appendix A
Standard Drive Parameters
[Pr - 2.11]
Preset Velocity 7
Ultraware Name
Preset Velocity 7
Range
-6000…6000
Default
0
Units
Rotary motors: rpm; Linear motors: mm/s
When Enabled
Immediately
Applicable Operating Mode
Preset
Modbus Address
213
[Pr - 2.12]
Manual Velocity Limit
Ultraware Name
Manual Velocity limit
Range
1…6000
Default
5000
Units
Rotary motors: rpm; Linear motors: mm/s
When Enabled
Servo-Off -> Setting
Applicable Operating Mode
Follower, Analog Velocity, Preset
Modbus Address
214
[Pr - 2.13]
Velocity Limit Mode
Ultraware Name
Velocity Limits: Velocity Limit Mode
Range
Value
Description
0x0
Disabled
0x1
Limited by
[Pr - 2.12]
.
0x2
Limited by Analog Speed
Command Value (except
Analog Speed Mode).
0x3
Limited by lesser one
between
[Pr - 2.12]
and
Analog Speed Command.
Default
0
When Enabled
Servo-Off -> Setting
Applicable Operating Mode
All
Modbus Address
215