Read Fault Contents (EHY)

Jog (JOG)

Attribute Value

Command EHY

Description Read

faults

See Read Fault Detailed Data (DIE) on page 44

for alternative fault data.

Format STX ID # EHY F1 : BSS ETX

Data Argument

Description

F1

Fault Number. Range is 0x01…0x08
where latest fault status is stored in 0x01, and oldest fault is
stored in 0x08.

Response Format

STX ID $ EHYE FCode FChars : BSS ETX

Data Data

Description

FCode Fault

Code.

See

Appendix C

for a list of fault codes.

FChars

Fault Name Abbreviated. See

Appendix C

.

Usage Note

Use this command to find out more about one of the eight faults.
To receive all fault statuses, use EHY * command below.

Attribute Value

Command EHY

*

Description

Read all fault codes

Format

STX ID # EHY * : BSS ETX

Data Argument

Description

*

Asterik (*) means all faults

Response Format

STX ID $ EHY Fcode1&Fcode2&...Fcode8 : BSS ETX

Data Data

Description

Fcode1…Fcode8 Fault

Code.

See

Appendix C

for a list of fault codes.

Attribute Value

Command JOG

Description

Jog forward or reverse

Format STX ID # JOG

P1 : BSS

ETX

Data Argument

Description

P1

0 = prepare for jog operation
+ = jog forward
- (dash) = jog reverse

Response ACK

Usage Note

To keep jogging, send JOG command more than once within 500 ms.
To end Jog mode, send SVROF