Read fault contents (ehy), Jog (jog), Read fault contents (ehy) jog (jog) – Rockwell Automation 2071-Axx Kinetix 3 Component Servo Drive Serial Host Command Reference Manual User Manual
Page 41
Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
41
General Commands (ASCII)
Chapter 3
Read Fault Contents (EHY)
Jog (JOG)
Attribute Value
Command EHY
Description Read
faults
See Read Fault Detailed Data (DIE) on page 44
for alternative fault data.
Format STX ID # EHY F1 : BSS ETX
Data Argument
Description
F1
Fault Number. Range is 0x01…0x08
where latest fault status is stored in 0x01, and oldest fault is
stored in 0x08.
Response Format
STX ID $ EHYE FCode FChars : BSS ETX
Data Data
Description
Code.
See
for a list of fault codes.
FChars
Fault Name Abbreviated. See
Usage Note
Use this command to find out more about one of the eight faults.
To receive all fault statuses, use EHY * command below.
Attribute Value
Command EHY
*
Description
Read all fault codes
Format
STX ID # EHY * : BSS ETX
Data Argument
Description
*
Asterik (*) means all faults
Response Format
STX ID $ EHY Fcode1&Fcode2&...Fcode8 : BSS ETX
Data Data
Description
Fcode1…Fcode8 Fault
Code.
for a list of fault codes.
Attribute Value
Command JOG
Description
Jog forward or reverse
Format STX ID # JOG
P1 : BSS
ETX
Data Argument
Description
P1
0 = prepare for jog operation
+ = jog forward
- (dash) = jog reverse
Response ACK
Usage Note
To keep jogging, send JOG command more than once within 500 ms.
To end Jog mode, send SVROF