beautypg.com

Group 9 - motor controls – Rockwell Automation 2071-Axx Kinetix 3 Component Servo Drive Serial Host Command Reference Manual User Manual

Page 103

background image

Rockwell Automation Publication 2071-RM001B-EN-P - April 2013

103

Standard Drive Parameters

Appendix A

Group 9 - Motor Controls

[Pr - 9.00]

Standard Motor Flag

Ultraware Name

General: Motor Flag

Range Value

Description

0

Custom

1

Standard

Default

1

When Enabled

Servo-Off -> Setting -> After power cycle

Applicable Operating Mode

All

[Pr - 9.01]

Motor Type

Ultraware Name

General: Motor Type

Range

Value

Description

0

Rotary

1

Linear

2

Reserved

3

Reserved

Default

0

When Enabled

Servo-Off -> Setting -> After power cycle

Applicable Operating Mode

All

[Pr - 9.02]

Motor Resistance

Ultraware Name

Electrical: Resistance

Range

1…65,535

Units

Ohms * 256

When Enabled

Servo-Off -> Setting -> After power cycle

Applicable Operating Mode

All

[Pr - 9.03]

Motor Inductance

Ultraware Name

Electrical: Inductance

Range

1…65,535

Units

mH *256

When Enabled

Servo-Off -> Setting -> After power cycle

Applicable Operating Mode

All

[Pr - 9.04]

Motor Intermittent Current

Ultraware Name

Ratings: Intermittent Current

Range

1…32,767