Group 9 - motor controls – Rockwell Automation 2071-Axx Kinetix 3 Component Servo Drive Serial Host Command Reference Manual User Manual
Page 103

Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
103
Standard Drive Parameters
Appendix A
Group 9 - Motor Controls
[Pr - 9.00]
Standard Motor Flag
Ultraware Name
General: Motor Flag
Range Value
Description
0
Custom
1
Standard
Default
1
When Enabled
Servo-Off -> Setting -> After power cycle
Applicable Operating Mode
All
[Pr - 9.01]
Motor Type
Ultraware Name
General: Motor Type
Range
Value
Description
0
Rotary
1
Linear
2
Reserved
3
Reserved
Default
0
When Enabled
Servo-Off -> Setting -> After power cycle
Applicable Operating Mode
All
[Pr - 9.02]
Motor Resistance
Ultraware Name
Electrical: Resistance
Range
1…65,535
Units
Ohms * 256
When Enabled
Servo-Off -> Setting -> After power cycle
Applicable Operating Mode
All
[Pr - 9.03]
Motor Inductance
Ultraware Name
Electrical: Inductance
Range
1…65,535
Units
mH *256
When Enabled
Servo-Off -> Setting -> After power cycle
Applicable Operating Mode
All
[Pr - 9.04]
Motor Intermittent Current
Ultraware Name
Ratings: Intermittent Current
Range
1…32,767