Rockwell Automation Publication 2071-RM001B-EN-P - April 2013

123

Indexing Drive Parameters

Appendix B

[IN01.11]

Homing Time Limit

Ultraware Name

Homing Time Limit

Description

Drive fault when time for homing exceeds the homing
time limit.

Range Value

Description

0 …65,535

Homing time limit in
seconds

Default 60

Units seconds

Access Set

Changeable Status

Disable Drive

When Enabled

Disable Drive

Applicable Operating Mode

Indexing

Modbus Address

5215

[IIN01.12]

Stop Home Deceleration

Ultraware Name

Stop Home Decel

Description

The rate of drive deceleration used when homing is
stopped.

Range Value

Description

1 …2,147,483,647

Rate of drive deceleration
when homing is stopped.

Default 6250

Units N/A

Access Set

Changeable Status

Disable Drive

When Enabled

Disable Drive

Applicable Operating Mode

Indexing

Modbus Address

5216 …5217