Rockwell Automation 2071-Axx Kinetix 3 Component Servo Drive Serial Host Command Reference Manual User Manual
Page 91

Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
91
Standard Drive Parameters
Appendix A
[
Pr - 4.04]
Negative External Current Limit
Ultraware Name
Current Limits: Negative External
Range
0…500
Default
100
Units
% of motor rated continuous current
When Enabled
Immediately
Applicable Operating Mode
All
Modbus Address
[Pr - 4.05]
Overtravel Current Limit
Ultraware Name
Stopping Functions: Maximum Stopping Current
Range
0…500
Default
300
Units
% of motor rated continuous current
When Enabled
Immediately
Applicable Operating Mode
All
Modbus Address
[Pr - 4.06]
Initial Current Bias
Ultraware Name
Initial Current Bias
Description
Constant current applied when the drive enables. Meant
to hold vertical loads.
Range
-100…100
Default
0
Units
% of motor rated continuous current
When Enabled
Immediately
Applicable Operating Mode
All
Modbus Address