Rockwell Automation Publication 2071-RM001B-EN-P - April 2013

91

Standard Drive Parameters

Appendix A

[

Pr - 4.04]

Negative External Current Limit

Ultraware Name

Current Limits: Negative External

Range

0…500

Default

100

Units

% of motor rated continuous current

When Enabled

Immediately

Applicable Operating Mode

All

Modbus Address

404

[Pr - 4.05]

Overtravel Current Limit

Ultraware Name

Stopping Functions: Maximum Stopping Current

Range

0…500

Default

300

Units

% of motor rated continuous current

When Enabled

Immediately

Applicable Operating Mode

All

Modbus Address

405

[Pr - 4.06]

Initial Current Bias

Ultraware Name

Initial Current Bias

Description

Constant current applied when the drive enables. Meant
to hold vertical loads.

Range

-100…100

Default

0

Units

% of motor rated continuous current

When Enabled

Immediately

Applicable Operating Mode

All

Modbus Address

406