Pr - 2.03 – Rockwell Automation 2071-Axx Kinetix 3 Component Servo Drive Serial Host Command Reference Manual User Manual
Page 82

82
Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
Appendix A
Standard Drive Parameters
[Pr - 2.03]
Deceleration
Ultraware Name
Acceleration Limits: Deceleration
Range
1…2,147,483,647
Default
41667
Units
Rotary motors: 10
-2
*rev/s
2
; Linear motors: mm/s
2
When Enabled
Immediately
Applicable Operating Mode
Analog Velocity Input, Preset Velocity
Modbus Address
Pr-2.03[Lo] = 204, Pr-2.03[Hi] = 205
[Pr - 2.04]
S-Curve Time
Ultraware Name
Acceleration Limits: S-Curve Time
Range
0…5000
Default
0
Units
Milliseconds
When Enabled
Immediately
Applicable Operating Mode
All
Modbus Address
206
[Pr - 2.05]
Preset Velocity 1
Ultraware Name
Preset Velocity 1
Range
-6000…6000
Default
0
Units
Rotary motors: rpm; Linear motors: mm/s
When Enabled
Immediately
Applicable Operating Mode
Preset
Modbus Address
207
Pr - 2.06]
Preset Velocity 2
Ultraware Name
Preset Velocity 2
Range
-6000…6000
Default
0
Units
Rotary motors: rpm; Linear motors: mm/s
When Enabled
Immediately
Applicable Operating Mode
Preset
Modbus Address
208